GA-36HP230V specifications

GA-36HP230V Specs

SpecificationValue
Indoor/Outdoor ModelsGA-36HP230V/I GA-36HP230V/O
BrandGENIEAIRE
System TypeHeat Pump
Nominal Capacity36000 BTU
Power Supply208/230V,1Ph,60Hz
Cooling Capacity Standard (Btu/hr)36000
Cooling Capacity Range (Btu/hr)8300-37500
Cooling Input Standard (W)3790
Cooling Input Range (W)340-3048
Cooling Current Standard (A)16.8
Cooling Current Range (A)1.45-13.3
Cooling EER (Btu/hr/W)9.5
Cooling SEER (Btu/hr/W)18
Heating Capacity Standard (Btu/hr)36000
Heating Capacity Range (Btu/hr)10900-37360
Heating Input Standard (W)3790
Heating Input Range (W)610-3720
Heating Current Standard (A)16.8
Heating Current Range (A)2.66-16.2
Heating COP (W/W)2.78
Heating HSPF (Btu/hr/W)12
Cooling at 5F Capacity (Btu/hr)42400
Cooling B2 Capacity (Btu/hr)37400
Cooling B2 EER (Btu/hr/W)11.74
Heating at 17F Capacity (Btu/hr)24700
Heating at 17F COP (W/W)2.03
Heating at -4F Capacity (Btu/hr)18900
Heating at -4F COP (W/W)1.68
Heating H42 5F Capacity (Btu/hr)2000
Heating H42 5F COP (W/W)2.01
Heating H42 5F Capability Ratio (%)64.44
Moisture Removal (L/h)4.48
Min Circuit Ampacity Indoor (A)3
Max Fuse Indoor (A)15
Min Circuit Ampacity Outdoor (A)28
Max Fuse Outdoor (A)35
Compressor ModelKTF250D22UMT
Compressor TypeROTARY
Compressor BrandGMCC
Compressor Capacity (W)8095
Compressor Input (W)2200
Compressor Rated Current (A)18
Refrigerant Oil TypeVG74
Refrigerant Oil Charge (ml)670
Indoor Fan ModelZKFP-58-8-1-5
Indoor Fan Input (W)58
Indoor Fan RLA (A)0.5
Indoor Fan Speed Hi (r/min)1200
Indoor Fan Speed Mi (r/min)960
Indoor Fan Speed Lo (r/min)600
Indoor Airflow Turbo (m3/h)1350
Indoor Airflow Hi (m3/h)1110
Indoor Airflow Mi (m3/h)760
Indoor Airflow Lo (m3/h)560
Indoor Airflow Turbo (CFM)794.12
Indoor Airflow Hi (CFM)652.94
Indoor Airflow Mi (CFM)447.06
Indoor Airflow Lo (CFM)329.41
Indoor Noise Hi dB(A)54
Indoor Noise Mi dB(A)45
Indoor Noise Lo dB(A)40
Indoor Unit Width (mm)1259
Indoor Unit Depth (mm)283
Indoor Unit Height (mm)362
Indoor Unit Width (inch)49.57
Indoor Unit Depth (inch)11.14
Indoor Unit Height (inch)14.25
Indoor Unit Net Weight (kg)19.4
Indoor Unit Gross Weight (kg)25.2
Indoor Unit Net Weight (lb)42.77
Indoor Unit Gross Weight (lb)55.56
Outdoor Fan ModelZKFN-120-8-2
Outdoor Fan Input (W)150
Outdoor Fan RLA (A)0.5
Outdoor Fan Speed 1 (r/min)1150
Outdoor Fan Speed 2 (r/min)1050
Outdoor Fan Speed 3 (r/min)900
Outdoor Fan Speed 4 (r/min)850
Outdoor Airflow (m3/h)3800
Outdoor Airflow (CFM)2235.29
Outdoor Noise Level dB(A)65
Throttle TypeEXV+Throttle valve
Outdoor Unit Width (mm)946
Outdoor Unit Depth (mm)410
Outdoor Unit Height (mm)810
Outdoor Unit Width (inch)37.24
Outdoor Unit Depth (inch)16.14
Outdoor Unit Height (inch)31.89
Outdoor Unit Net Weight (kg)68.1
Outdoor Unit Gross Weight (kg)72.1
Outdoor Unit Net Weight (lb)150.13
Outdoor Unit Gross Weight (lb)158.95
Refrigerant TypeR410A
Refrigerant Charge (kg)3.4
Refrigerant Charge (oz)120
Additional Charge per Metre (g/m)30
Additional Charge per Foot (oz/ft)0.32
Design Pressure High (PSIG)550
Design Pressure Low (PSIG)340
Liquid Line Diameter (mm)9.52
Liquid Line Diameter (inch)03/08/26
Gas Line Diameter (mm)15.9
Gas Line Diameter (inch)05/08/26
Max Refrigerant Pipe Length (m)65
Max Refrigerant Pipe Length (ft)213.25
Max Height Difference (m)30
Max Height Difference (ft)98.42
Connection Wiring16#x4//
Thermostat TypeRemote Control
Indoor Cooling Temp Range C6-32
Indoor Cooling Temp Range F60-90
Indoor Heating Temp Range C0-30
Indoor Heating Temp Range F32-86
Outdoor Cooling Temp Range C-15-50
Outdoor Cooling Temp Range F5-122
Outdoor Heating Temp Range C-15-24
Outdoor Heating Temp Range F5-75
Qty per 20ft36
Qty per 40ft76
Qty per 40HQ88
ModelGA-36HP230V

YOUR LOCAL HVAC CONNECTION

Come talk comfort.

Genie Air Conditioning and Heating, Inc.
15041 Calvert St.
Van Nuys, CA 91411

Get directions
(818) 785-4151

[email protected]

Hours of operation

Monday–Friday
7:30 AM – 5:00 PM
Saturday
8:00 AM – 2:00 PM
Pacific Time

GUIDED EQUIPMENT ASSISTANT

Ask Genie

1. Your installation
Heat pump or heat strip?

A heat pump transfers heat; a heat strip uses electric resistance heating. The right choice depends on the unit, climate, and available electrical supply.

2. Space & measurements

If there is an existing sleeve, measure its outside dimensions in inches to the nearest ⅛ inch. Leave unknown measurements blank.

3. Power & quantity

Use known circuit information or ask a qualified electrician. Do not open electrical equipment to check.

4. How can we reach you?

Opens your email app with the details addressed to [email protected]. Review and send there. Nothing is submitted automatically.